FixForge › Marine › Marine Electronics › Raymarine ACU Power & Motor Cables Swapped
Raymarine ACU-150 / ACU-400 “Power & Motor Cables Swapped”
On a Raymarine Evolution autopilot this message has two very different causes. Either the drive motor and the power supply really are on the wrong terminals of the Autopilot Control Unit (ACU), or the ACU is one of the units built in June and July 2022 that Raymarine has recalled, and the ACU software has disabled it on purpose. The serial number tells you which, so read it before you touch a wire.
Last Updated: November 2026

Fast Answer
Read the ACU serial number first. If it is an ACU-150 (E70430) numbered 0720203 or 0620001 to 0720131, or an ACU-400 (E70100) numbered 0420339, 0920329 or 0620001 to 0720151, the unit is in Raymarine's product recall: stop using it and contact a Raymarine certified dealer, who will replace it free of charge if it is affected. If the serial is outside those ranges, switch off the power to the ACU and check that the motor and power cables are on the right terminals. If the wiring is right and the alarm stays, check the ACU software: version 3.15 fixed a few units outside the recall range that were still being shut down.
p70 Diagnostics menu, MFD Network list, or the product label under the ACU cover.
Units built June–July 2022, in the ranges below. If in doubt, Raymarine says stop using it.
Power off first. Motor cables on the Power terminals (and vice versa) raises MOTOR POWER SWAPPED.
v3.14 added the recall check; v3.15 corrected units that were not recalled but still shut down.
Why This Message Appears
Raymarine documents two separate things that end in the same warning:
- A real wiring fault. The Evolution error table lists MOTOR POWER SWAPPED: on the ACU-Series unit, the Motor cables are connected to the Power terminals, and vice versa. The fix Raymarine gives is to switch off the power to the unit and reconnect correctly.
- The 2022 recall. Raymarine's ACU software history says version 3.14 (August 2023) added a software check to see whether an ACU-150 or ACU-400 is within the recall range (June/July). If it is, the ACU alarms “Power & Motor cables are swapped” and will disable the ACU from working. On a recalled unit the message does not mean the wiring is wrong.
Raymarine documents two causes: the ACU recall and power and motor cables connected the wrong way round. The serial number check comes first.
Step 1: Find the ACU Serial Number
Raymarine's safety bulletin gives three ways to find it:
- From a p70 / p70R / p70s / p70Rs pilot controller: from the main screen with no menu displayed, press MENU, then select Set-up, Diagnostics, About System, and Continue. The serial number is shown above the ACU item in the device list.
- From a Raymarine multifunction display: on an Axiom running LightHouse 4, select Settings from the Homescreen, then the Network tab, and find the ACU in the list of devices. The serial number is the 7-digit number at the end of the device label. Raymarine notes the procedure is very similar on older displays.
- From the label on the unit: on the ACU-150, remove the 2 screws that secure the cover and detach it; on the ACU-400, unlock the cover screw and detach the cover. The part number (E70430 or E70100) is on the product label, and the 7-digit number below it is the serial number.
If you go for the label, switch the vessel's power supply off first. Raymarine's Evolution installation instructions warn: do NOT connect or disconnect equipment with the power switched on, unless instructed to do so.
Step 2: Compare It With the Recall Ranges
The recall covers a small quantity of ACU-150 and ACU-400 units manufactured between June and July 2022 that were fitted with a drive component of incorrect specification. Raymarine says no other autopilot system components are affected.
- ACU-150 (E70430): 0720203, and 0620001 to 0720131.
- ACU-400 (E70100): 0420339, 0920329, and 0620001 to 0720151.
The serial reads as month, year and unit number: Raymarine's notice explains 0620001 as June 2022 number 0001 and 0720131 as July 2022 number 0131.
Why it matters: the bulletin says the ACU may function correctly, but the component could fail prematurely. This could prevent the autopilot from driving in one or both directions, or cause it to turn the tiller or wheel fully in one direction, potentially giving rise to a loss of directional control unless or until the system is disconnected. The UK government recall notice (2307-0191) describes the same hazard.
If your unit is in range, or you are not sure: stop using it immediately and contact your Raymarine certified dealer. The dealer checks the unit and, if it is in the affected group, installs a replacement ACU free of charge. The replacement is covered by the remainder of your existing warranty. Raymarine also offers a direct return through its customer portal, linked from the bulletin.
Before the unit goes back, the bulletin suggests noting your existing Dockside Wizard settings. After the replacement is fitted, Raymarine strongly recommends re-calibrating the autopilot: complete the Dockside Wizard, then a Seatrial Calibration or Compass Linearization, depending on the pilot controller.
Step 3: Outside the Range? Check the Wiring
If your serial number is not in the list, treat the alarm as Raymarine's MOTOR POWER SWAPPED error.
- Switch off the power to the ACU.
- Open the cover and find the separately labelled POWER and MOTOR terminal blocks. The ACU-400 label shown in Raymarine's bulletin marks them side by side.
- Confirm that the cable from the drive unit is on MOTOR and the cable from the battery or breaker is on POWER. If they are reversed, reconnect them correctly.
- Restore power and check whether the alarm clears.
Step 4: Check the ACU Software
The software history lists two releases that matter here:
- V3.14, August 2023: the recall check described above.
- V3.15, September 2023: corrects for a few ACU serial numbers that were NOT affected by the recall software but still shuts the ACU down.
So a unit outside the recall range, with correct wiring, that still shows the alarm on v3.14 is the case v3.15 was written for. Two warnings from the same page before you update: you must update the EV sensor before updating your ACU, and when updating through an a/c/e/eS/gS Series display the MFD software must be at v13.37 or above. Raymarine also notes that the included R4 pilot software requires recalibration of the autopilot once complete.
When to Contact Raymarine
Any unit in the recall range goes to a certified dealer, whatever the wiring looks like. Raymarine's US support line in the bulletin is (+1) 603-324-7900. If a unit outside the range keeps showing the alarm after the wiring check and the v3.15 update, contact Raymarine support rather than reconnecting the drive by trial and error.
Parts reference
| Part | Part number / spec | Notes |
|---|---|---|
| ACU-150 | E70430 | Recall range: 0720203, and 0620001 to 0720131. |
| ACU-400 | E70100 | Recall range: 0420339, 0920329, and 0620001 to 0720151. |
| Safety bulletin | Document 84295 (Rev 2), 19 July 2023 | Replacement ACU free of charge for affected units. |
| ACU software | V3.14 (Aug 2023), V3.15 (Sept 2023) | Update the EV sensor before the ACU. |
Sources
Specifications, part numbers and procedures on this page come from the manufacturer documents and the recall notice below. Where a point comes from owner reports instead, the text says so.
- Raymarine, ACU-150 & ACU-400 Product Recall (support page)
- Raymarine ACU-150 / ACU-400 Important Safety Warning, Product Recall, Document 84295 (Rev 2), 19 July 2023
- GOV.UK, Product Recall: Raymarine ACU-150 / ACU-400 Autopilot System (2307-0191)
- Raymarine, Evolution Autopilot ACU Software (software history and update warnings)
- Raymarine Evolution EV-1 Autopilot Installation Instructions, 87472 Rev 2: Error: MOTOR POWER SWAPPED
- Raymarine Evolution EV-1 Autopilot Installation Instructions, 87472 Rev 2: Switch off power supply
Raymarine's bulletin has you remove the ACU cover screws to read the serial label. Switch the autopilot off first.
Check Price on Amazon →As an Amazon Associate, FixForge earns from qualifying purchases.