Raymarine eS Series Won't Power On or Stuck in a Reboot Loop

The eS Series (eS75, eS77, eS78, eS97, eS98, eS127 and eS128) is out of production, so a display that will not start or dies at the logo is worth diagnosing properly before you price a replacement. Raymarine's installation instructions split the fault in two: a unit that does not turn on or keeps turning off, and a unit that will not boot and loops.

Last Updated: November 2026

Illustrated diagram of a marine chartplotter showing the power cable, fuse, and display connections
Illustrated diagram — not a photo of an actual installation. Your setup may vary.

Fast Answer

For a dead or cutting-out display: check the fuse, confirm the power connector is fully inserted and locked, flex the cable near the display to see if it reboots, and measure voltage as close to the unit as possible with current flowing. The operating range is 10.8 V dc to 31.2 V dc. For a display that shows the logo and restarts: re-flash the latest software, and as a last resort run the Power on Reset, which deletes settings, waypoints and tracks.

Check the fuse

5 A in-line for the 3-pin power cable, 15 A for the combined power and data cable.

Seat and flex the connector

It must be fully inserted and locked. Flex the cable near the display and watch for a reboot.

Measure voltage at the unit

10.8 V dc to 31.2 V dc, measured with the current flowing.

Re-flash, then reset

For a logo loop: latest software first, Power on Reset as a last resort.

Two Different Faults

Section 7.2 of the eS Series installation instructions (document 87250-2) treats these separately, and the fix differs.

  • Product does not turn on or keeps turning off. Raymarine's checks: a blown fuse or tripped breaker, the power cable and its connector, voltage drop across connectors and fuses, and an insufficient power source.
  • Product will not boot up (re-boot loop). Causes listed: power supply and connection, and software corruption.

A display that beeps when you press Power but stays dark is running. That is a different fault from one with no signs of life.

Step 1: Fuse and Breaker

The fuse rating depends on which power cable the display uses, and the manual gives both:

  • 3-pin power cable: 5 A in-line fuse, or a 3 A thermal breaker if only one device is on it. The spares list gives this cable for the eS7x.
  • Combined power and data cable: 15 A in-line fuse, or a 15 A thermal breaker if only one device is on it. The spares list gives this cable for the eS9x and eS12x.

Raymarine's note on a repeat failure: if the fuse keeps blowing, check for cable damage, broken connector pins or incorrect wiring. Do not fit a larger fuse.

Step 2: Connector and Cable

  1. Check that the power cable connector is fully inserted into the unit and locked in position.
  2. With the display on, flex the power cable near the display connector. Raymarine's instruction is to see whether this causes the unit to re-boot or lose power.
  3. With the unit under load, use a multimeter to check for high voltage drop across all connectors and fuses.

Step 3: Voltage at the Display

The eS7x, eS9x and eS12x all take a nominal 12 V dc to 24 V dc supply with an operating range of 10.8 V dc to 31.2 V dc. For an insufficient power source, Raymarine says to check the supply voltage as close to the unit as possible to establish the actual voltage when the current is flowing. A battery that reads well with nothing switched on tells you little.

Step 4: Logo Then Restart

If power checks out and the display still loops, the manual's remaining cause is software corruption. Its instruction is to try re-flashing the latest software from the Raymarine website. Before that, it is worth removing the chart card: Raymarine forum staff have asked owners with intermittent eS boot failures to remove the card and test, and one owner's eS75 ran better with a third-party chart card out.

The last resort is a Power on Reset. The manual warns that it deletes all settings, presets and user data such as waypoints and tracks. The sequence it gives:

  1. Power the unit off.
  2. Power the unit back on.
  3. When the LightHouse logo appears, press and hold the Power button. The Raymarine Initialization screen is displayed.
  4. On touch-only displays, press the Power button again to select "1 - Reset to factory defaults". A 7 second countdown begins.
  5. On Non-Touch and HybridTouch displays, press the WPT/MOB button.

Raymarine forum staff have described a variant for some units: hold the Back button while the unit boots until the Initialization screen appears, then press WPT. If the manual's sequence does not bring up the Initialization screen, that is the one to try.

When the Display Needs Service

In one forum case, an eS128 that showed the logo and then died after a LightHouse 3 upgrade, Raymarine's reply was that if a power-on reset fails to resolve the issue, the unit may have a hardware fault, with referral to a Raymarine repair centre. Get a repair quote before deciding, because the eS Series is discontinued.

Parts reference

PartPart number / specNotes
eS7x power cableR70159 (straight, 1.5 m); A80221 (angled)3-pin cable. Fuse: 5 A in-line.
eS9x / eS12x power and data cableR62379 (straight, 1.5 m); R70029 (angled)Combined cable. Fuse: 15 A in-line.
In-line fuse5 A (3-pin cable) or 15 A (combined cable)Replace like for like.

Sources

Specifications, part numbers and procedures on this page come from the manufacturer documents below. Where a point comes from owner reports instead, the text says so.

Raymarine eS7x Power Cable (R70159)

The straight 1.5 m 3-pin power cable listed in the eS Series spares table for eS75, eS77 and eS78.

Check Price on Amazon →

As an Amazon Associate, FixForge earns from qualifying purchases.

Raymarine eS9x / eS12x Power and Data Cable (R62379)

The straight 1.5 m combined power and data cable listed for eS9x and eS12x displays.

Check Price on Amazon →

As an Amazon Associate, FixForge earns from qualifying purchases.