FixForge › Marine › Marine Electronics › Simrad GO Keeps Rebooting
Simrad GO XSE Keeps Rebooting or Powering Off
Simrad's GO XSE manuals contain no troubleshooting section for random restarts, so there is no official fault tree to follow. What the installation manual does give is an exact power specification and a description of how the yellow power-control wire behaves. Owner reports of this fault line up with those two things, plus the chart card.
Last Updated: November 2026

Fast Answer
Check the 3 A ATC blade fuse and its holder. Measure voltage at the display's power plug with everything else on the boat running: the GO XSE needs 12 V DC within 10 to 17 V. Find the yellow wire in the power cable. It must be either taped off, tied to red after the fuse, or wired to the ignition accessory output. A yellow wire making intermittent contact will switch the unit on and off. Then run the display with the chart card removed.
Supplied as a 3 A ATC blade fuse in a holder on the red wire. Same rating for 5, 7, 9 and 12 inch units.
12 V DC, 10 to 17 V minimum to maximum. Not suited to 24 V systems.
It is a power-control input. Loose or shorting, it turns the unit on and off by itself.
Run without it. Simrad warns that copying files to a chart card can damage the chart data.
What the Manual Does and Does Not Say
The GO XSE Installation Manual (document 988-11093-003) and the GO XSE/XSR Operator Manual (988-11105-004) do not list causes for a rebooting display, and they give no point at which to contact service for it. The operator manual states only that the unit does not contain any field serviceable components.
So this guide is a process of elimination built on the manual's wiring section. The three things owners on boating forums most often report fixing are a ground or power connection, the yellow wire, and the chart card. Each of those has a documented correct state you can check against.
Step 1: Fuse and Supply Voltage
- Supply voltage: 12 V DC, with a minimum to maximum range of 10 to 17 V DC.
- Protection: reverse polarity, and temporary over-voltage to 18 V.
- Recommended fuse rating: 3 A. The box includes a fuse holder and a 3 A ATC blade fuse.
- Draw: 12 W (900 mA at 13.5 V) for the 5, 7 and 9 inch; 20 W (1500 mA at 13.5 V) for the 12 inch.
The manual is direct about system voltage: the unit has a voltage rating of 12 V DC and is not suited for use with 24 V DC systems.
- Pull the fuse and inspect the holder contacts as well as the fuse. A corroded holder drops voltage even with a good fuse in it.
- Confirm red goes to positive through the 3 A fuse and black to negative.
- Measure DC voltage at the display end of the power cable with the engine running and your usual loads on. A reading that dips toward 10 V when another load starts explains a restart.
Step 2: The Yellow Power-Control Wire
The manual describes the yellow wire as an input that will turn on the unit when power is applied. It documents three valid ways to finish it:
- Not used: the unit turns on and off by the power button. Leave the yellow wire disconnected and tape or heat-shrink the end to prevent shorting.
- Tied to red after the fuse: the device turns on immediately when power is applied. In this mode the unit cannot be powered down by the power button, only put into standby with the backlight off.
- Wired to ignition: connect the yellow wire to the accessories output of the engine key switch. The manual adds that engine start batteries and house batteries should have a common ground connection.
Any other state is a fault. A bare yellow end touching a terminal, a crimp that has worked loose where yellow joins red, or an ignition feed with no common ground will all produce a display that powers up and down unprompted.
On 7, 9 and 12 inch units the power cable has four cores: red, black, yellow and a blue external-alarm wire. The 5 inch uses a combined power and NMEA 2000 plug whose thicker cable carries red, black and yellow.
Step 3: Chart Card
Remove the microSD chart card and run the display without it for a trip. If the restarts stop, the card is the cause. The manual carries a related warning: do not download, transfer or copy files to a chart card, because doing so can damage chart information on the chart card.
Step 4: Restore Defaults
If power, wiring and the card all check out, restore settings. First back up: the installation manual describes exporting waypoints, routes, tracks and the settings database to a memory card and re-importing them from the Files page.
Restore defaults is in the System settings dialog. The operator manual says it restores selected settings to default factory values, and warns that if waypoints, routes, or tracks and trips are selected, they are permanently deleted. Leave those unticked unless you have a backup.
If It Continues
There is nothing inside the display to service. Simrad's route is a service report: on the About page of System settings, select Support, save the report to a memory card and send it to Simrad support. Include when the restarts happen and what you have already ruled out.
One thing to disregard: forum posts describe a "hard reset" done by holding the power key until the unit beeps. No such sequence appears in the GO XSE manuals. The power key's documented behaviour is press and hold to turn the unit on or off.
Parts reference
| Part | Part number / spec | Notes |
|---|---|---|
| Power cable, GO7 / GO9 / GO12 XSE | Simrad 000-00128-001 | Four-core: red, black, yellow, blue. |
| Power and NMEA 2000 cable, GO5 XSE | Simrad 000-13171-001 | Combined plug. |
| Fuse | 3 A ATC blade | Same rating on every GO XSE size. |