FixForge › Marine › Marine Electronics › Lowrance Ghost Keeps Shutting Off

Lowrance Ghost Trolling Motor Keeps Shutting Off

A Ghost that runs for a while and then quits signals why with beeps and flashes of the direction indicator. Lowrance's own troubleshooting table has an entry for exactly this, "Motor loses power after a short running time", and it points at the battery and the supply wiring.

Last Updated: November 2026

Illustrated schematic diagram of a marine dual 12V battery wiring setup with a battery isolator
Illustrated diagram — not a photo of an actual installation. Your setup may vary.

Fast Answer

Listen as it shuts off. Four long beeps with four long flashes means the battery level is below threshold and the unit will shut off. Five long beeps with five long flashes is high temperature. Five long beeps with five short flashes is a propulsion motor error. For a low-battery shut-off, check charge with the battery test key, confirm the pedal is set to your system voltage (24 V or 36 V), and inspect every power connection between the batteries and the foot pedal, including the 50 A breaker and the wire size.

Count the beeps

4 long: battery below threshold. 5 long: temperature or a motor error, set by the flashes.

Test the batteries

Battery test key with the motor not running. HIGH is above 23.6 V or 35.4 V.

Check the voltage setting

The Power LED under the heel must match your system. The default is 24 V.

Check breaker and wire

50 A breaker. 8 AWG extension up to 15 ft, 6 AWG for 20 to 25 ft.

What the Ghost Does Before It Quits

The direction indicator is the set of three illuminated arrows on top of the upper unit. Lowrance's operator manual pairs its flashes with audible tones. Three entries describe a motor that stops on its own:

  • 4 long beeps, 4 long flashes: battery level below threshold. Unit will shut off.
  • 5 long beeps, 5 long flashes: high temperature.
  • 5 long beeps, 5 short flashes: propulsion motor error.

One more tone is useful. Four short beeps with the indicator off means the trolling motor startup sequence has completed.

Step 1: Batteries

For "Motor loses power after a short running time", the manual's first action is to check battery charge level. The foot pedal has a test for it. The note in the manual matters: the battery capacity should only be checked when the trolling motor is not running. Press the test key to activate the indicator LEDs under the heel of the pedal.

  • HIGH: on if the battery is above 23.6 V on a 24 V system, or above 35.4 V on a 36 V system.
  • MID: on at 23.0 to 23.6 V, or 34.5 to 35.4 V.
  • LOW: on below 23.0 V, or below 34.5 V.

Lowrance's resolution for a propulsion motor error includes performing a load test on the batteries. The manual also says to check the condition of the battery against the battery supplier's recommendations, to recharge as soon as possible after each use, and to check terminals weekly for corrosion or dirt.

Step 2: The Voltage Setting

The Ghost runs on a 24 V DC or 36 V DC system, and the pedal has to be told which. The default voltage setting is 24 V. Two Power LEDs under the heel show the current choice: one for 24 V, one for 36 V. The battery capacity LEDs above use different thresholds for each, so on the wrong setting they are being read against the wrong scale.

To change it, from the operator manual:

  1. Enter configuration mode by pressing and holding Configurable key 2 and Configurable key 3 until the Power LEDs start blinking. The direction indicator flashes two times and two long beeps sound.
  2. Press the Battery test key repeatedly until the Power LED matching your supply (24 V or 36 V) lights.
  3. Press and hold the Battery test key to save. The direction indicator flashes three times and three long beeps sound.
  4. Exit configuration mode by pressing and holding Configurable keys 2 and 3 until the Power LEDs stop blinking.

Lowrance notes that an incorrect voltage setting will not damage the trolling motor. A factory reset returns system voltage to its default, so re-check this after any reset.

Step 3: Power Wiring and the Breaker

Disconnect the motor from the batteries before you touch any of this. The manual's second action for a motor that loses power is to check power wires and connections and make sure that the correct cable diameter is used.

All wiring on a Ghost is made to and from the foot pedal, so the supply path is batteries, breaker, any extension wire, then the pedal's red and black leads. Lowrance's installation manual gives the numbers:

  • Circuit breaker: 50 A at 24 V DC, or 50 A at 36 V DC. Navico's trolling motor safety document gives the same figure as a fuse rating.
  • Extension wire, 1.5 to 4.5 m (5 to 15 ft): 8.5 mm2 (8 AWG).
  • Extension wire, 6 to 7.5 m (20 to 25 ft): 13.5 mm2 (6 AWG).

Undersized extension wire and tired connections lose voltage under load, and the motor sees a lower voltage than the batteries are holding. Work along the run:

  • Make sure terminals are clean and corrosion free. Lowrance says to use fine sandpaper or emery cloth to clean them.
  • Check the battery leads for cuts or abrasions and repair or replace if necessary.
  • Check the foot pedal's electrical terminals. The maintenance schedule has you confirm yearly that the terminal screws are not loose and reapply Tef-Gel to the terminals if needed.
  • Any joins in extended cable should be soldered or crimped and insulated, and kept as high as possible to limit water ingress.
  • Check battery connections for proper polarity.

Step 4: Five Long Flashes: Heat

For the high temperature error, Lowrance's resolution is short: stop the trolling motor and disconnect power, and park the boat in a cool spot if possible. Let it cool before you run it again.

Step 5: Five Short Flashes: Propulsion Motor Error

Always disconnect the motor from the batteries before cleaning or checking the propeller. Then follow Lowrance's order:

  1. Inspect the propeller shaft for fishing line, and remove it if present. Line can be wedged between the propeller and the lower unit, so take the propeller off to look.
  2. Check all power connections between the trolling motor pedal and the batteries.
  3. Perform a load test on the batteries.

Removing the propeller takes a 17 mm deep socket. Use hand tools only: Lowrance warns against power tools on the propeller nut. On refitting, align the drive pin with the slot in the propeller and torque the nut to 13 Nm (10 lb ft).

Step 6: Software

If the shut-off comes with five long beeps and ten fast triple flashes, that is a software version mismatch, and the manual refers you to its "Force a software upgrade" procedure. Ordinary updates run from the Lowrance: Fishing and Navigation app over Bluetooth, or from a microSD card of 32 GB or smaller in a compatible display on the same NMEA 2000 network. Do not disconnect power from the trolling motor while an update is in progress.

When It Is a Service Centre Job

Lowrance draws the line in the error table. If a propulsion motor error persists after the line, connection and load-test checks, contact a service center. If the propeller shaft is damaged, contact a service center. The same instruction follows a power cycle that does not clear a configuration error or an invalid pedal angle error. Do not attempt to disassemble the 360 breakaway.

Parts reference

PartPart number / specNotes
Circuit breaker50 A at 24 V DC, or 50 A at 36 V DCOn the positive (red) supply wire. Lowrance says closest available to the fuse rating.
Extension wire8.5 mm2 (8 AWG) for 1.5 to 4.5 m; 13.5 mm2 (6 AWG) for 6 to 7.5 mSolder or crimp and insulate all joins.
Propeller nutM10 nylock; 17 mm deep socket; 13 Nm (10 lb ft)Hand tools only. Apply the included anti-seize compound unless fitting a brass nut.

Sources

Specifications, part numbers and procedures on this page come from the manufacturer documents below. Where a point comes from owner reports instead, the text says so.

50 A Trolling Motor Circuit Breaker

Lowrance specifies a 50 A breaker for the Ghost on 24 V and 36 V systems. Check the breaker's DC voltage rating covers your system.

Check Price on Amazon →

As an Amazon Associate, FixForge earns from qualifying purchases.

6 AWG Marine Battery Cable

Lowrance's recommended extension wire size for 20 to 25 ft runs. Shorter runs to 15 ft are listed at 8 AWG.

Check Price on Amazon →

As an Amazon Associate, FixForge earns from qualifying purchases.