FixForge › Marine › Marine Electronics › Minn Kota Ulterra Won't Stow or Deploy

Minn Kota Ulterra Won't Stow or Deploy

An Ulterra that ignores the Stow/Deploy button, stops partway or sounds an error tone has a short list of causes, and Minn Kota's owner's manual sets out a recovery order: a reset, a stow from the motor base, a low-battery workaround, and a manual stow that should be the last thing you try. This page covers the Ulterra described in owner's manual 2207111, used with i-Pilot or i-Pilot Link: the Ulterra 80 on 24 volts and the Ulterra 112 on 36 volts. The Ulterra QUEST uses different procedures, summarised near the end.

Last Updated: November 2026

Illustrated schematic diagram of a marine dual 12V battery wiring setup with a battery isolator
Illustrated diagram — not a photo of an actual installation. Your setup may vary.

Fast Answer

Press Stow/Deploy twice in quick succession: one press does nothing by design, and on the foot pedal the button only works in Ulterra Mode. Check that the green System Ready light stays on, because low voltage stops a stow or deploy. If the motor is deployed and stuck, run the Trim/Stow Reset: power off, power on, wait 3 seconds, then press the Power button 3 times within 2 seconds. If the remote is the problem, hold the Power button for 10 seconds to stow from the base.

Press twice

Two quick presses of Stow/Deploy are required. On the foot pedal, switch to Ulterra Mode first (amber MODE light on).

Check voltage

24 volts for the Ulterra 80, 36 volts for the Ulterra 112. The green System Ready light must stay on.

Trim/Stow Reset

Motor deployed. Power off, power on, wait 3 seconds, press Power 3 times within 2 seconds.

Stow from the base

With the green light on, press and hold the Power button for 10 seconds. The motor begins to stow.

Read the Two LEDs First

The Indicator Panel on the base of the motor has a Power button and two lights.

  • System Ready (green): illuminated when the motor is operating. If the green light does not remain illuminated after power up, the manual says this is an indicator of insufficient voltage or power.
  • Status (red): illuminated when the motor is stowed, not illuminated when it is deployed, and flashing while the motor is being stowed or deployed.

The Ulterra must be powered on and off manually. The remote will not turn the motor on. It also powers itself off after 1.5 hours of inactivity in the stowed position, so a motor that "won't deploy" at the ramp may simply be off.

Step 1: Press Twice, in the Right Mode

The manual's advanced troubleshooting says this is not a problem with the motor: it is designed to require two quick presses of the Stow/Deploy button to avoid accidental deployment. That applies to the i-Pilot remote and to the corded foot pedal.

On the foot pedal, the Stow/Deploy button only stows and deploys in Ulterra Mode. Press the MODE button on the right side of the pedal, just above the Speed Control knob. The amber MODE light on the pedal's Indicator Panel is illuminated in Ulterra Mode. In Normal Mode the same button turns the prop on and off.

Step 2: Voltage

The Ulterra 80 is designed to operate on 24 volts and the Ulterra 112 on 36 volts. With low voltage, the manual says, the motor will not stay on when the Power button is pressed and released, or the LEDs will go out when the command is sent to deploy or stow.

Disconnect the batteries before touching wiring. Then:

  1. Check each battery's voltage, and the combined voltage across the series-connected set.
  2. Check the voltage at the battery positive and negative wires directly at the motor, to find a voltage drop.
  3. Check that wiring, plug connections and battery series connections are clean and secure, and check the circuit protection devices.
  4. Look at the remote. If the trolling motor battery icon is flashing, battery charge is too low for operation.

Step 3: An Error Tone Means Something Is Binding

An error tone on a deploy command indicates a current limit issue: something is restricting or preventing movement of the motor unit and shaft. If the motor contacts an object while stowing, press Stow/Deploy to reverse the cycle and clear it.

  • Check that the power cable to the steering housing is not pinched between the housing and the aluminum mounting base.
  • Clean the composite shaft. Dirt makes it stick or bind in the steering housing. The manual suggests a silicone-rich, water-based spray.
  • The manual's basic list for a motor that fails to stow or deploy adds: ensure that the manual tilt knob is engaged.

The manual also describes removing the right front motor ramp as a test. If the motor still does not deploy properly with the ramp removed, it says to contact an authorized Minn Kota service center. The same goes for the other cause it names: damage to the wires running along the motor base to the three Hall Effect sensors, often pinched or cut by mounting bolts. A cut sensor wire makes the motor inoperative.

Step 4: Trim/Stow Reset Procedure

Use this when the Ulterra will not trim or stow, or when it rotates to horizontal or vertical at the wrong point because the trim module has lost its position count. The motor must be in the deployed position, with the shaft vertical and the latch pin engaged. Keep clear: the motor runs an automated sequence.

  1. Press and hold the Power button to turn the motor off. Confirm the green System Ready LED is off.
  2. Press the Power button until the green LED illuminates.
  3. Wait 3 seconds.
  4. Press the Power button 3 times consecutively within a 2 second period.
  5. The red and green LEDs flash continuously. The motor positions itself, trims up to the mount, then trims down approximately 6 inches.

If the Ulterra does not reset, repeat the procedure. If the second attempt fails, Minn Kota says to contact an authorized service center or call (800) 227-6433.

Step 5: Stow From the Motor

If the remote has stopped working, check that the green System Ready LED is on, then press and hold the Power button on the Indicator Panel for 10 seconds. The red and green LEDs flash alternately and the motor begins to stow.

Step 6: Stalled at an Angle on Low Batteries

If the batteries lose power to the level that the motor will not stow, the manual says it will most likely stall at a 45 degree angle. Its instruction is to re-engage power, deploy the motor, trim it to its highest setting and turn power off until the batteries can be recharged. Then attempt the stow again.

Step 7: Manual Stow, the Last Resort

Only when all three methods above have failed. The manual's caution is direct: once the motor has been manually stowed, it will be non-operational until it is manually reset by an authorized service center.

  1. With the motor deployed, remove the two screws holding the Right Sideplate with a #3 Phillips screwdriver.
  2. Loosen the screw on the Manual Tilt Knob with a #2 Phillips screwdriver, then pry the knob up with a flat blade screwdriver until it releases from the metal plates.
  3. Pull out the Trim Release Handle on the side of the Trim Housing. Holding it out, lift the Trim Housing and Shaft up off the Steering Housing.
  4. Release the Latch Pin Bracket, lift and rotate the assembly, and pull the Lower Unit onto the Mount Ramps.
  5. Secure the Lower Unit with the Emergency Strap supplied with the motor. Its D-ring hooks into the Base Extrusion below the removed sideplate.

Minn Kota warns that lifting the Trim Housing exposes power connections, and that the Tilt Motor Shaft and Bracket create a shear point. Keep fingers and metal objects clear.

If the Lower Unit Stows Crooked

If the lower unit no longer turns to lie flat on the ramps, the Park Position has been lost, because the lower unit was turned by hand, or knocked by an obstruction, while the motor was deployed with the power off. Deploy normally, start a stow, and stop it with Stow/Deploy before the motor pulls onto the ramps. Hold the Power button about three seconds to turn the motor off, wait about five seconds, and turn the lower unit by hand so it lies horizontally at 90 degrees to the mounting base. Power on and test.

Ulterra QUEST Is Different

The Ulterra QUEST manual uses a Manual Stow Bypass in place of the procedure above. After a bypass, most motor functions are disabled until a Manual Stow Bypass Recovery is carried out. Its Trim Reset uses the same three presses of the Power button within two seconds, with a blue System Status LED and an orange Stowed LED. A flashing red System Status LED means an error: check the Wireless Remote Diagnostic menu for the code. Follow the QUEST manual for those motors.

Parts reference

PartPart number / specNotes
Circuit breakerMinn Kota MKR-19, 60 ampThe sizing table lists 60 Amp for an 80 lb motor at 24 VDC and a 112 lb motor at 36 VDC.
Emergency StrapSupplied with the motorSecures the lower unit on the Mount Ramps after a manual stow.
Shaft cleanerSilicone-rich, water-based sprayFor a composite shaft that sticks or binds in the steering housing.

Sources

Specifications, part numbers and procedures on this page come from the manufacturer documents below. Where a point comes from owner reports instead, the text says so.

Minn Kota MKR-19 60 Amp Circuit Breaker

The breaker Minn Kota's owner's manual recommends for motors that need 60 amp protection. Confirm the rating for your thrust and voltage in the sizing table first.

Check Price on Amazon →

As an Amazon Associate, FixForge earns from qualifying purchases.